35 –
ZN ZT RC In: L
10 00 00 RF: 1
5. A display will appear, showing a summary of that zone's programming.
If the zone is not programmed, the display will appear as shown here. If
checking a zone's programming, and it is programmed satisfactorily,
press [#] to back up one step and enter another zone number, if
desired. Otherwise, press [
] to continue.
Zone Number
10 Zone Type
Perimeter 03
Entry for Zone Type 03
shown
6. Each zone must be assigned a zone type, which defines the way in
which the system responds to faults in that zone. Enter the zone type
desired (or change it, if necessary). Available zone types are:
00 = Zone Not Used 08 = 24 Hr Aux
01 = Entry/Exit #1, Burglary 09 = Fire
02 = Not used 10 = Interior w/Delay
03 = Perimeter 20 = Arm–Stay*
04 = Interior Follower 21 = Arm–Away*
05 = Trouble Day/Alarm Night 22 = Disarm*
06 = 24 Hr Silent 23 = No Alarm Response
07 = 24 Hr Audible
(EX: Relay activation)
* These are special zone types used with 5800 series wireless pushbutton
units which will result in arming the system in the STAY or AWAY mode, or
disarming of the system, depending on the selection made. A button
programmed for these functions will report the zone number of the button as
the user number that armed/disarmed to the central station.
Press [
] to continue.
10 Report Code
1st 03 2nd 12 3C
7. Enter the report code. The report code consists of 2 hexadecimal digits,
each in turn consisting of 2 numerical digits. For example, for a report
code of "3C", enter [0][3] for "3" and [1][2] for "C."
(Refer to the
SYSTEM COMMUNICATION
section for more information
about report codes and report code formats.)
Press [
] to continue.
10 Input Dev: LP #
Rf Trans. RF: 1
8. Enter the transmitter input device type as follows:
3 = RF (supervised RF transmitter)
4 = UR (unsupervised RF transmitter)
5 = BR (button type RF transmitter - unsupervised)
(Refer to the separate Programming Guide for input types.)
Press [
] to continue.
10 Input Dev: LP#
RF Trans. RF: 1
9. The cursor should now be flashing above the loop number. The default
is "1." To accept this, press [
]. If a different loop number is being used
on this transmitter, enter the loop number (1–4) and press [
] to
continue (see the loop designations for various transmitters in the
separate Programming Guide). The loop number must be entered
here, whether using Zone Programming or Sequential Mode to
"enroll" transmitters.
10 Learn S/N?
0 = No, 1 = Yes 0
10. If the transmitter’s serial number has not been previously “enrolled,” you
may enter the enroll mode now by either entering "1" (Yes)
or
by
pressing the upper left-hand button of the “program tool”. If using the
program tool, move to the physical location of the transmitter to be
enrolled before pressing the button. A single short beep will verify that
the button has been pressed. The system will respond to the first serial
number transmitted after the [
] key on the keypad or the button of the
program tool is pressed.
Enter "0" (No) if you wish to enroll the transmitter later, using the
“sequential” mode in
Section 13. SEQUENTIAL MODE
.
If "0" (No) is entered, go to step 13 (skip steps 11 and 12).
10 Input S/N: L
A X X X–X X X X
11. This prompt is displayed if "1" (Yes) is entered in response to the "Learn
S/N?" prompt. The serial number may be enrolled by one of two methods:
a) Enter the 7-digit serial number printed on the transmitter using a
Alpha keypad, or
b) Activate the transmitter by faulting
or
restoring the input you wish to
use for that zone (e.g., press a button, open or close a door, etc.).