Output Relay Displays
Enter Relay No.
(00 = Quit) 01
Upon pressing
80, this screen will appear. Enter the Relay Number 01, 02,
03, or 04 for a 4204 (or 00 to end these entries). Press the [
] key to
continue.
The [
] key is used to accept an entry and advance to the next prompt. The
[#] key is used to revert back to the last question to check or change an
entry. Press [
] to go forward again.
02 A EV ZL ZT
STT 0 0 0 00
This screen displays a summary of the current Relay START programming
(for this example, relay 02 has been selected).
Press the [
] key to continue.
02 A EV ZL ZT
STP – – 0 00
This screen displays a summary of the current Relay STOP programming.
Press the [
] key to continue.
02 Relay Action
No Response 0
Enter the desired relay action as listed below. Press the [
] key to continue.
0 = No response 2 = Close and Stay Closed
1 = Close for 2 seconds 3 = Continuous Pulse on & off (1 sec ON, 1 sec OFF)
02 Start Event
Not Used 0
Enter the event to START the relay:
0 = Not used; 2 = Fault; 1 = Alarm; 3 = Trouble
A zone list must be used in conjunction with an event. If a zone type/system
operation is to be used instead of an event, enter 0.
Press the [
] key to continue.
02 Start: Zn List
No List 0
If a zone list will be used to START the relay action, enter the zone list number
(to be programmed in field
81): 1, 2, or 3. If not used, enter 0. Press the [
]
key to continue.
02 Start: Zn Typ
Not Used 00
If a zone type or system operation will be used to START the relay action,
enter the appropriate two-digit code (see table that follows). If not, enter 00.
Press the [
] key to continue.
CHOICES FOR ZONE TYPES
00 = Not Used 05 = Trouble Day/Alarm Night 08 = 24 Hr Aux
01 = Entry/Exit 06 = 24 Hr Silent 09 = Fire
03 = Perimeter 07 = 24 Hr Audible 10 = Interior w/Delay
04 = Interior Follower
CHOICES FOR SYSTEM OPERATION
20 = Arming–Stay 33 = Any Burglary Alarm 39 = Any Fire Alarm
21 = Arming–Away 34 = Code + # + 7 Key Entry 40 = Bypassing
22 = Disarming (Code + OFF) 35 = Code + # + 8 Key Entry 41 = AC Power Failure
31 = End of Exit Time 36 = At Bell Timeout** 42 = System Batt. Low
32 = Start of Entry Time 38 = Chime 58 = Duress
**Or at Disarming, whichever occurs earlier.
02 Stop: Zn List
No List 0
If a zone list will be used to STOP, or restore, the relay action, enter the zone list
(ZL) number 1, 2, or 3 (to be programmed in
81 mode). If not used, enter 0.
Press the [
] key to continue.
02 Stop: Zn Typ
Not Used 00
If a zone type or system operation will be used to STOP the relay action, enter
the appropriate two digit code (see the "ZT" choices listed above). If not, enter
00. Press the [
] key to continue.
02 A EV ZL ZT
STT 0 0 0 00
This screen again displays a summary of the current relay START
programming.
Press the [
] key to continue.
02 A EV ZL ZT
STP – – 0 00
This screen again displays a summary of the current relay STOP programming.
Press the [
] key to continue.